Ordinance 1989-20ORDINANCE NO. 89 - 20 ORDINANCE OF THE COUNCIL OF THE CITY OF GILROY SETTING FORTH A SEISMIC HAZARD IDENTIFICATION PROGRAM FOR UNP~INFORCED MASONRY BUILDINGS. WHEREAS, the State of California has enacted Senate Bill 547, requiring seismic hazard identification of unreinforced masonry buildings; and WHEREAS, the City Council desires to lessen the risks to life and property of the citizens of the City of Gilroy as posed by earthquakes; and WHEREAS, the City Council has concluded that it wishes to implement a seismic hazard identification program to require owners of unreinforced masonry buildings to investigate the potential hazards of their buildings; NOW, THEREFORE, the City Council of the City of Gilroy does adopt this ordinance as follows: SEISMIC HAZARD IDENTIFICATION PROGRAM FOR UNREINFORCEDNASONR¥ BUILDINGS Sections: 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Purpose Definitions Scope of program Building owner notification Recording Engineering reports Letters of intent Mitigation options Historic properties City review of engineering reports and letters of intent Building tenant notification Progress reports to City Council Interpretations Penalties Effective date. Section 1: Purpose. It is generally acknowledged that the City of Gilroy is located in a geographic area of high seismic risk, due to its proximity to both the San Andreas and Calaveras faults, and may reasonably be expected to experience moderate to severe ground shaking in the event of a significant local earthquake. Such ground shaking could result in serious injury or loss of life due to damage or collapse of buildings. Historically, unreinforced masonry buildings have been shown to be especially vulnerable. The purpose of this ordinance is to promote public safety by identifying those buildings in the City of Gilroy which exhibit structural deficiencies in their capacities for earthquake resistance, and by determining the severity and extent of those deficiencies in relation to their potential for causing injury or loss of life. Section 2: definitions apply: Definition. For purposes of this ordinance the following -1- ORDINANCE NO. 89 - 20 (a) "Civil engineer or structural engineer" means a licensed civil or structural engineer registered by the State of California pursuant to the rules and regulations of Title 16, Chapter 5 of the California Administrative Code. (b) "Uniform Building Code (UBC)" is as published by the International Conference of Building Officials, Whittier, California, as adopted by the City of Gilroy. (c) "Unreinforced masonry (URM) building" means any building containing walls and/or columns constructed wholly or partially of masonry without at least fifty percent (50%) of the reinforcement required by the 1985 edition of the UBC, and includes: 2. 3. 4. 5. Unreinforced brick masonry Unreinforced concrete masonry Hollow clay tile Adobe or unburned clay masonry Stone masonry. (d) Other terms are as defined in the 1985 edition of the UBC. Section 3: Scope of Program. Owners of all URM buildings in the City of Gilroy, except as exempted below, shall be required to have an engineering report submitted to the City's Building Division, to determine the existence, nature, extent and severity of structural deficiencies in their buildings' capacities for earthquake resistance which could result in damage or collapse with possible Injury or loss of life. (a) Exempted Buildings. The following buildings are exempted from complying with this ordinance: Be Residential buildins with five (5) or fewer dwelling units. Warehouses or similar structures not used for human habitation, except for warehouses or structures housing emergency services equipment or supplies. Buildings which have already been structurally upgraded in substantial accordance with either the 1973, or later, edition of the UBC or the City of Los Angeles Division 88 Standard for URM Buildings. Section 4: Building Owner Notification. Owners of buildings included in the scoppe of this program shall be notified within six (6) months of the enactment of this ordinance by the Building Division of the City of Gilroy that each such building has been included in the City's list of potentially hazardous URM buildings, and is required to have an engineering report submitted to the City. Section 5: Recording. At the time of building owner notification, the Chief Building Official shall file with Office of the County Recorder a certificate stating that the subject building falls within the scope of this ordinance, has been included in the City's list of potentially hazardous URM buildings, and is required to comply with the provisions contained herein. At such later time as each such identified building has either been determined as excludable from the City's list by further investigation, or has undergone mitigation of Its hazards to the satisfaction of the Chief Building Official, the Chief Building Official shall then file with the Office of the County Recorder a certificate stating that the building has been removed from the potentially hazardous classification. -2- ORDINANCE NO. 89 - 20 Section 6: Engineering Reports. Owners of identified buildings shall submit engineering reports to the Building Division of the City of Gilroy as follows: (a) Timeframe. Engineering reports shall be submitted within two (2) years of building owner notification. (b) Authorized Preparers. Engineering reports shall be prepared by civil or structural engineers, as previously defined herein, who are familiar with seismic analysis and design. (c) Purpose. The purpose of each such engineering report shall be to investigate, in a thorough and unambiguous fashion, a building's structural systems that resist earthquake forces, and to evaluate their adequacy to resist the seismic design forces as specified herein. (d) Engineering Standards. The engineering standards to be used in preparation of engineering reports shall be the 1985 edition of the UBC as modified by Appendices A and B of this ordinance. (e) Format. The format for engineering reports shall be as outlined in Appendix B of this ordinance, or other equivalent format approved in writing by the Chief Building Official. (f) Availability. Copies of engineering reports submitted shall be available to the public for review at the Building Division upon request. Section 7: Letters of Intent. A letter of intent shall be submitted within ninety (90) days of submittal of each engineering report, and shall describe in general fashion how the building owner intends to approach hazard reduction of his or her building. Section 8: Mitigation Options. Options available to the building owner for approaching hazard reduction include, but are not limited to, the following: (a) Structural rehabilitation of the building to meet or exceed the seismic provisions of the engineering standards referenced herein. (b) Change in use of the building to a residential or warehouse occupancy exempted from compliance with this ordinance, as previously described herein, as may be allowed by other City ordinances. (c) Sale of the building to a new owner, who shall then bear the responsibility of hazard reduction. (d) Vacating the building pending further investigation of possible alternatives. (e) Demolition of the building, or portions thereof, to eliminate the potentially hazardous conditions. Section 9: Historic Properties. Any building which qualifies as "historical property" as determined by an appropriate governmental agency under Section 37602 of the Health and Safety Code shall be retrofitted in accordance with the State Historical Building Code. -3- ORDINANCE NO. 89 - 20 Section 10: City's Review of Engineering Reports and Letters of Intent. The Building Division shall review the documents submitted for each identified building for conformance to this ordinance. The Building Division may, at its option, engage the services of consulting civil or structural engineers to assist in evaluation of documents submitted. Costs of each such review shall be recovered by fees assessed upon the building owner at the time of submittal of documents, based upon the time required for review of any structural rehabilitation plans subsequently submitted for building permit purposes for work directly related to compliance with this Ordinance. Section 11: Building Tenant Notification. Owners of each identified building shall provide each of their tenants with written notification that a seismic investigation of their building has taken place, and that the engineering report documenting the investigation is available for review at the Building Division. Such notification shall occur within ninety (90) days of submittal of each engineering report. Each building owner shall also submit to the Building Division written confirmation of tenant notification, in the form of a signed affidavit or other equivalent means as approved by the Chief Building Official. Section 12: Progress Reports to City Council. The Building Division shall prepare annual progress reports to the City Council on the implementation of this ordinance and its effects on voluntary hazard reduction by building owners. Section 13: Interpretations. The interpretation of the Chief Building Official shall prevail on matters relating to the implementation of this ordinance. Section 14: Penalties. Nonconformance with this ordinance is unlawful. Violation constitutes an infraction and is subject to civil prosecution under the laws and ordinances of the City of Gilroy. Section 15: Effective Date. This ordinance shall become effective on the thirty-first day after the day of its passage. PASSED AND ADOPTED this 4th day of December, 1989, by the following vote: AYES: NOES: COUNCILMEMBERS: GAGE, HALE, KLOECKER, MUSSALLEM, NELSON, VALDEZ and HUGHAN. COUNCILMEMBERS: None ABSENT: COUNCILMEMBERS: None ATTEST: APPROVED: -4- ORDINANCE NO. 89 - 20 APPENDIX A PROCEDURES FOR INVESTIGATION OF URM BEARING WALL BUILDINGS (a) Preliminary Field Survey. From existing plans or from field investigation prepare framing plans for roof and upper floors noting all beams, trusses, and major lintels at bearing walls. Prepare elevations of all URM walls noting the location and size of all openings in the walls. (b) Items for Special Investigation. (1) Identify and include on the plans all parts of the vertical load carrying system that may act as ties to lateral load resisting elements, to determine the elements that may control the relative displacement between the building's base and roof. (2) Identify and include on the plans all undamaged interior crosswalls that are continuous between the ground floor and roof noting if these are connected to the upper floor or roof by methods other than attachment of wall and ceiling finishes. (3) Examine and draw the relationship of the roof or floor framing to the ceiling framing (if separate) to determine the method if any of their interconnection. (4) Identify and include on the plans the support system for any URM walls that are not continuous to the base of the building noting the materials used for this support. (e.g. steel frame). (5) Identify and include on the plans a description of the floor and roof sheathing and their attachment. Note any difference in materials on a given level that could lead to substantial variations in diaphragm stiffness. Note the sizes and locations of openings in diaphragms adjacent to URM walls. Identify the roof covering system used and note if there are locations where it is on a cricket or other superimposed deck. A thorough investigation of the roof diaphragm is necessary to permit the evaluation of the compatibility of its stiffness with the out-of-plane stability of the URM walls of the story immediately below the roof as required in section (c) of the analysis procedure of this appendix. (c) InvestiGation of Existing Anchorage of URM Walls to UDDer Floor and Roof. Indicate the locations of ali"existing wall anchors on the roof/floor framing plans and specify their spacing, size and method of connection. If existing anchors are to be utilized as connections for resisting lateral force in the analysis these will require testing as specified in section (e)l. (d) InvestiGation of Existina URM Walls. Investigate the following items if they occur in the building, and determine: (1) The thickness of URM walls at all levels and locations of any changes in thickness. Substantial changes in wall thickness or stiffness shall be considered in the analysis for out-of-plane and in-plane wall stability. Variations in wall..stiffness caused by openings such as small windows and doors need not be considered. (2) materials used for lint~ or arches at openings ~d their bearing areas and connection to supporting columns or piers. The materials used for columns or piers supporting lintel beams or arches. (3) The heights of parapets, cornices and gable ends of URM walls above the uppermost existing anchorages. (4) The anchorage or bonding of terra cotta, cast-stone brick veneer or similar facing materials to the backup wythes of brickwork at cornices and other architectural appendages. (5) The coursing of exterior wythes of masonry, the bonding of wythes of masonry, and the materials used in each wythe. An examination of the wall joint between wythes (collar joint) must be made at each in-plane shear test location to estimate the percentage of wythe to wythe mortar coverage and the estimate shall be reported with the results of the tests. Wythes of walls Dot bonded as described below shall be considered veneer. The veneer wythe shall not be included in the effective thickness of the wall used to calculate the height-to- thickness ratio and the shear capacity of the wall, and methods for its adequate anchorage must be devised. All units of URM bearing and non-bearing walls shall be laid with full shoved mortar joints; all head, bed and collar joints shall be solidly filled with mortar; and the bonding of adjacent wythes of multi-wythe walls shall be as follows: The facing and backing shall be bonded so that not less than 4 percent of the wall surface of each face is composed of headers extending not less than four inches into the backing. The distance between adjacent full length headers shall not exceed 24 inches vertically or horizontally. In walls where a single header does not extend through the wall, headers from the opposite sides shall overlap at least four inches, or headers from opposite sides shall be covered with another header course overlapping the header below at least four inches. (6) The condition of mortar joints and the locations of any existing cracks or damaged portions of wall elements. (e) Testinq. The testing of existing wall anchorage systems must be made to determine an average capacity when these anchors are to be used in the analysis of the building's current resistance to lateral forces. The testing of existing URM walls to determine the allowable bed-joint shear is required for all buildings. ~ (1) Existing Wall Anchors in URM Walls. Five percent of the existing rod anchors shall be tested in pullout by an approved testing laboratory. The minimum tested quantity shall be four per floor or roof level with two tests where framing is perpendicular to the wall and two where framing is parallel to the wall. The test apparatus shall be supported on the masonry wall at a minimum distance of the wall thickness from the anchor tested. Where due to obstructions this is not possible, details of the condition encountered and the alternate method used must be included in the test report, with calibration adjustment for conditions where the reaction of the test apparatus contributes tq the tension value of the anchor. The rod anchor shall be given a preload of 300 pounds prior to establishing a datum for recording elongation. The tension load reported shall be recorded at 1/8 inch relative movement of the anchor to the adjacent masonry wall surface. The allowable resistance of existing anchors shall be 40 percent of the average of those tested anchors having the same wall thickness and joist orientation. (2) In-Place Shear Test of Brick Masonry. The bed joints of the outer wythe of the masonry shall be tested in shear by laterally displacing a single brick relative to the adjacent bricks in that wythe. The opposite head joint of the brick to be tested shall be removed and cleaned prior to testing. Steel bearing plates of the full dimension of the brick shall be inserted at each end of the test jack. The bearing plates shall not contact the mortar joints. The shear stress shall be based on the gross area of both bed joints and shall be that at which movement of the adjacent brick is first observed. The minimum quality mortar in 80 percent of the shear tests shall not be less than the total of 30 psi when reduced to an equivalent zero axial stress. If the larger height-to-thickness ratios allowed by footnotes %5 and %6 of Table A-2 are to be utilized in the analysis, all shear tests taken at the top story must be included in the 80 percent or'the shear tests used to determine the minimum mortar shear strength. The minimum quantity of tests shall be as follows: At each story not less than two per wall line or line of wall elements providing a common line of resistance to lateral forces, with not less than one per 1500 square feet of wall surface and not less than a total of eight per building. In single story buildings the wall above the lintel beam at an open storefront need not be tested. The exact test locations shall be determined by the engineer responsible for the investigation and noted on the documents submitted to the City. The tests should be conducted at least two brick courses above or below the bond course and be distributed vertically to include a variety of dead load surcharge conditions. Test locations shall be representative of the mortar conditions throughout the entire building, taking into account variations in workmanship, variations in weathering of exterior surfaces and variations of interior surfaces due to deterioration caused by leaks and condensation of water and/or by other deleterious substances contained within the building. (a) STANDARDS FOR THE ANALYSIS AND EVALUATION OF UN'REINFORCED MASONRY BEARING WALL BUILDINGS Structural Analysis Procedures accordance with the following equation: (1) The total seismic forces should be computed in V =ZIKCSW WHERE: The value of KCS shall equal .100 The value of Z and I shall equal 1.0. The value of W shall be as defined in Chapter 23 of the 1985 Uniform Building Code (UBC). (2) Parts or portions of the building shall be analyzed for lateral loads in accordance with Chapter 23 of the 1985 UBC but not less that the value from the following equation: Fp = ICpSWp WHERE: The product of I__S shall be 0.75 The value of Cp shall be as set forth in Table 23-J of the 1985 UBC and shall equal 0.16 for diaphragms. The value of W_~ shall be as defined in the 1985 UBC. Exception: URM walls may be analyzed as indicated in Section (b) below. (3) The structural elements of the building required to be analyzed shall include the following: Wall height-to-thickness ratio and in-plane shear forces. Tension bolts (in bending) if used to resist lateral forces. Parapets for out-of-plane loading. Diaphragm stress and diaphragm chords at floors and roof. (4) Anchorage and interconnection of all parts, portions and elements of the structure resisting lateral forces shall be analyzed in accordance with the 1985 UBC and the formula in Subsection (2) above. A complete and continuous load path from every part or portion of the structure to the foundation shall be shown to exist for the required lateral forces. All parts, portions and elements of the structural systems shall be shown to be interconnected by an adequate positive means. (5) Except as modified herein, the lateral analysis of the building shall be in accordance with the analysis specified in the 1985 UBC. Stresses in existing materials and construction utilized to transfer seismic forces shall conform to either those permitted by the 1985 UBC or those permitted for types of materials and configurations specified in Table A-3 or those described in Section (b) below. When calculating' shear or diagonal tension stresses due to seismic forces, existing masonry shear walls may be allowed to resist 1.0 times the required forces in lieu of the 1.5 factor required by the 1985 UBC. (6) Masonry walls not anchored to all floors and roof to resist a minimum of 200 pounds per linear foot acting normal to the wall at the level of the floor or roof shall be considered inadequate. No allowable tension stress will be permitted in URM walls, except as permitted by section (b)l of this appendix. URM walls not capable of resisting the required design forces specified in this section shall be deemed inadequate. In addition to seismic forces, URM walls shall be analyzed as specified in Chapter 24 of the 1985 UBC to withstand all vertical loads. Exception: URM Walls which carry no design loads other than their own weight may be considered veneer if they adequately anchored to elements which are not part of the existing lateral force resisting system. See section (d) 5 under Procedures for Investigation to determine if existing walls mus% be considered as veneer. (7) When stresses in existing lateral force resisting elements are due to a combination of dead and live plus seismic loads, the allowable working stress specified in the 1985 UBC may increased by 100 percent. However, no increase will be permitted in the stresses allowed in Section (b) below and the stresses in members due to only seismic and dead loads shall not exceed the values permitted in the 1985 UBC. In addition, the calculated tensile fiber stress due to seismic forces may be reduced by the full direct stress due to vertical dead loads. (b) Materials of Construction Standards (1) Unreinforced masonry walls analyzed in accordance with this section may provide support for roof and floor construction and resistance to lateral loads under the conditions set forth below. The bonding of such walls shall conform to those specified in Section (d) 5 of the Procedures for Investigation. Tension stresses due to seismic forces acting normal to the wall may be neglected if the wall does not exceed the height-to thickness ratio and the allowable in-plane shear stresses due to seismic loads set forth in Tables A-2 and A-4 respectively. If the wall height-to-thickness ratio exceeds the specified limits, the wall will be considered inadequate unless braced by vertical members designed to satisfy the requirements of the 1985 UBC. The deflection of such bracing members at design loads shall not exceed one-tenth of the wall thickness. Exception: The wall may be supported by flexible vertical bracing members that comply with the requirements of Section (a) 2 of the analysis procedure if the deflection at design loads is not less than one-quarter nor more than one-third of the wall thickness in the story under consideration. Any existing or new vertical bracing used for this purpose shall be attached to floor and roof construction independently of existing wall anchors and the horizontal spacing of the members shall not exceed one-half the unsupported height of the wall or ten feet, whichever is greater. (2) Minimum Acceptable Quality of Existing URM Walls. All unreinforced masonry walls utilized to carry vertical loads and seismic forces parallel and perpendicular to the wall plane shall be tested as specified in Section (e) 2 of the Procedures for Investigation. All masonry used to resist seismic forces shall be undamaged by shear failure cracking and be of a quality not less than the minimum standards established or shall be considered inadequate. Pointing of all masonry wall joints may be performed prior to the testing if joints are raked and cleaned to remove loose and deteriorated mortar. Mortar pointing shall be Type S or N, except masonry cements shall not be used. All preparation and pointing shall be done under the continuous inspection of a special inspector whose reports shall be included in the testing report. The design seismic in-plane shear stresses shall be related to test results in accordance with Table A-4. Intermediate. values between 5 and 10 psi may be interpolated. Compression stresses for unreinforced masonry having a minimum design shear value of 3 psi shall not exceed 100 psi and design tension values shall not be permitted. (3) Existing Roof, Floors, and Walls. Existing undamaged materials, including wood shear walls may be analyzed as part of the lateral load resisting system, provided that the stresses in these materials do not exceed the values shown in Table A-3. New plywood shear walls designed in accordance with the 1985 UBC may be recommended to strengthen portions of the existing seismic resisting system. Diaphragm chord stresses of horizontal diaphragms ~shall be developed in existing materials or be considered inadequate. (4) Minimum URM Wall Anchorage. Ail URM walls shall be anchored at both floors and roof by existing rod anchors at a maximum spacing of six feet and be secured to the joists or rafters to develop the required forces. At the building corners at roof and floor levels combination shear and tension anchors shall be located not more than two feet horizontally from the inside corners of the wall. Testing of existing rod anchors shall be conducted according to Section (e) 1 of the Procedures for Investigation. Walls without anchors having the necessary locations, spacing or capacity will be considered inadequate. (5) Minimum Vertical Support. Where trusses or beams other than rafters or joists and beams supporting walls above open storefronts are supported on URM piers, these piers must be evaluated and shown to provide adequate vertical support during seismic loading or shall be independently supported by a vertical element other than the URM wall pier. (6) Minimum Parapet Bracing. Parapets and exterior wall appendages not capable of resisting the forces specified in Section (a) shall be considered hazardous. The maximum height of an unbraced UKM wall parapet above the roof sheathing, shall not exceed one and one-half times the thickness of the parapet wall. (c) Design Check for Compatibility of Roof Diaphragm Stiffness ~o the Out-of-Plane Stability of URM Walls. (1) General. The requirements of this section are in addition to the other analysis requirements of Section (a). This section contains a procedure for the evaluation of the out-of-plane stability of unreinforced masonry walls anchored to wood diaphragms. The relative stiffness and strength of a diaphragm Governs the amount of amplification of seismic Ground motion by the diaphragm, and therefore, a diaphragm stiffness and strength related check of the out-of-plane stability of URM walls must be performed. (2) Definitions. The following definitions are applicable to this section: CROSS WALL is a wood framed wall having a height-to-length ratio complying with 1985 UBC Section 4713(d) or Table 25-I and is sheathed with any of the materials described in Table A-1. The total strength of all cross walls located within any 40 feet length of diaphragm measured in the direction of the diaphragm span shall not be less than 30 percent of the strength of the diaphragm in the direction under consideration DEMAND CAPACITY RATIO (DCK) is a ratio where: DEMAND equals lateral forces due to 33 percent of the combined weight of the diaphragm and the tributary weight of walls and other elements anchored to t.he diaphragm. CAPACITY equals the diaphragm's total shear strength in the direction under consideration as determined using the values in Table A-1. D = the depth of the diaphragm, in feet, measured perpendicular to the diaphragm span. h/t = the height-to-thickness ratio of an unreinforced masonry wall. The height shall be measured between wall anchorage levels and the thickness shall be measured through the wall cross section at the level under consideration. L = span of diaphragm between masonry shear walls or steel Vc = the total shear capacity of cross walls in the direction of analysis immediately below the diaphragm level being investigated as determined by using Table A-1. vu = Maximum shear strength in pound per foot for a diaphragm sheathed with any of the materials Given in Table A-1. Wd = total dead load of the diaphragm plus the tributary weight of the walls anchored to the diaphragm, the tributary ceiling and partitions, and the weight of any other permanent building elements at the diaphragm level under consideration. (3) Design Check Procedure. The demand-capacity ratio (DCR) shall be calculated by the following equations: Buildings without crosswalls 0.33 Wd DCR = 2 vu D Buildings with crosswalls 0.33 Wd DCR = .2 vu D + Vc ~. DiaPhragm Deflection. The calculated DCR shall be the left of the curve in Figure A-5. Where the calculated DCR is outside (to the right) of the curve, the diaphragm's deflection limits are exceeded and cross walls are needed to reduce the deflection. URM Wall Out-of-Plane Stability. The DCR shall be calculated discounting any existing cross walls. If this DC~ value corresponding to the diaphragm span is to the right of the curve in Figure A-5, the region within the curve at and below the intersection of the diaphragm span with the curve may be used to determine the allowable h/t values per Table A-2. 7 TABLE A-1 ALLOWABLE VALUES FOR EXISTING WALLS AND DIAPHRAGMS ONLY FOR DETERMINATION OF THE DIAPHRAGM DEMAND / CAPACITY RATIO 1. Horizontal Diaphragms a. Roofs with straight sheathing and roofing applied directly to the sheathing. 100 PLF for seismic shear b. Roofs with diagonal sheathing and roofing applied directly to the sheathing. 250 PLF for seismic shear 2. Crosswalls I a. Plaster on wood or metal lath 200 PLF per side for seismic shear b. Plaster on gypsum lath 175 PLF per side for seismic shear c. Gypsum wallboard unblocked 75 PLF per side for seismic shear d. Gypsum wallboard edges blOcked 125 PLF per side for seismic shear Footnotes: 1. Materials must be undamaged and in good condition. TABLE A-2 ALLOWABLE VALUE OF HEIGHT-TO-THICKNESS (H/T) RATIO OF URM WALLS WITH MINIMUM QUALITY MORTAR ~' = ' Buildings with All Other Complying Crosswalls 3 Buildings One Story Building Walls First Story Walls of -Multi-Story Buildings Walls in Top Story of Multi-Story Buildings All Other Walls 13 - 16 4. ., 6 ~ 13 ! 16 I 15 9-144, ~, ~ ~ 9 16 ' 13 Footnotes: Minimum quality mortar shall be determined by testing described in Section (e) 2 of the Procedures for Investigation and shall include all top story tests in the 80 percent of tests used if the higher ratio values permitted in footnotes 5 and 6 are used. See section (c) for determination of the demand capacity ratio values to be used in conjunction with Figure A-5 to determine if the building can qualify as a building containing crosswalls. e Qualifying crosswalls are defined as interior walls of masonry or wood frame construction with surface finish of wood lath and plaster, 1/2 inch thick gypsum board, or solid horizontal wood sheathing. They may not exceed 40 feet horizontal separation, must be continuous through all stories and have a minimum length of 1-1/2 times the story height. The minimum mortar strengths required in footnotes # 5 and 6 shall be the test shear strength reduced by the effect of axial stress in the wall at the point of the test. 5. The larger height-to-thickness ratio may be used where mortar shear tests establish a minimum mortar shear strength of not less than 100 psi or where the tested mortar shear strength is not less than 60 psi and a visual examination of the vertical wythe-to-wythe (collar) joint indicates not less th~ 50 percent mortar coverage. 6. Where a visual examination of the collar joint indicates not less than 50 percent mortar coverage and the minimum mortar shear strength is greater than 30 psi but not less than 60 psi, the allowable h/t ratio may be determined by linear interpolation between the larger and smaller values given in direct proportion to the mortar shear strength. TABLE A-3 ALLOWABLE STRESS VALUES FOR EXISTING MATERIALS FOUND TO BE UNDAMAGED AND IN GOOD CONDITION 1. Horizontal Diaphragms Roofs with straight sheathing with the roof covering applied directly to the sheathing. Roofs with diagonal sheathing with the roof covering applied directly to the sheathing Floors with straight tongue and groove sheathing Floors with straight sheathing and finished wood flooring ee Floors with diagonal sheathing and finished wood flooring Floors or roofs with straight sheathing and plaster applied to the joists or rafters below 2'. Shear Walls Wood stud walls with lath and plaster in undamaged condition 3. Plain Concrete Footings 4. Douglas Fir Wood 100 PLF for seismic shear 400 PLF for seismic shear 150 PLF for seismic shear 300 PLF for seismic shear 450 PLF for seismic shear Add 50 PLF to the allowable values for items la and lc. 5. Reinforcing Steel ~ 6. Structural Steel ~ Footnotes: 1. Stresses may be increased for combination of loads as specified in Section (a) 7 of the Standards for Analysis and Evaluation. 100 PLF each side for seismic shear f'c = 1500 PSI unless otherwise shown by tests Same as 1985 UBC values for No. 1 Douglas Fir ~ f't = 18,000 PSI maximum f't = 20,000 PSI maximum 10 TABLE A-4 ALLOWABLE SHEAR STRESS FOR TESTED URM WALLS 80 Percent of Test Results in PSI Not Less Than: Allowable In-Plane Shear in PSI Based on Gross Area 30 + Axial Stress 40 + Axial Stress 50 + Axial Stress 100 + Axial Stress or more 3.0 4.0 5.0 10.0 (maximum) Footnotes: 1. The allowable shear stress may be increased by addition of 10 percent of the axial stress due to the weight of the wall directly above. 11 540 480 42( 36( 300-- 240- 180- 120 - 60-- REGION OF DEMAND/CAPACITY RATIOS WHERE CROSSWALLS MAY BE USED TO INCREASE H/T RATIOS REGION OF DEMAND/CAPACITY RATIOS WHERE H/T RATIOS OF "WITH CROSSWALLS" MAY BE USED REGION OF DEMAND/CAPACITY RATIOS WHERE H/T RATIOS OF "ALL OTHER BUILDINGS"SHALL BE USED O0 ! I ~ 't -~ - 1 2 3 4 5 6 DEMAND/CAPACITY RATIO = 0.33Wd / 2vuD OR 0.33Wd / (2vuD + Vc) FIGURE A-5 12 APPENDIX B: FORMAT FOR ENGINEERING REPORTS Engineering reports on URM buildings in the City of Gilroy shall incorporate the following format. I. DATA SHEET This sheet contains general information about the building, including its address, use/occupancy, .~ate of original construction, dates of any ~ubsequent structural alterations, names and addresses of the building's designers, if known, building area, number of stories, and occupant load calculations. II. BUILDING DESCRIPTION A. Configuration. Include descriptions of the building's size, shape, arrangements of structural elements, sizes and locations of openings in walls, roof and floors, any irregularities or discontinuities, non-structural elements (appendages, parapets, facades), and adjacent buildings if relevant. B. Construction Materials. observed conditions. Indicate types and present-day C. Site Geology. Provide information as required by the Chief Building Official for any special site or soil conditions. III. PLANS OF EXISTING CONSTRUCTION The following plans shall be included, to the degree of detail required to adequately show the seismic integrity of existing conditions. ae B. C. D. Ee F. G. H. Site Plan Roof Plan Floor Plans (showing any interior crosswalls) Roof Framing Plan (and ceiling framing if a separate system) Floor Framing Plans Foundation Plan Exterior Elevations Interior Wall Elevations (of any-interior URM partition walls and other crosswalls) Structural Building Section(s) Structural Details (for all lateral load connections) Appendix B, Page 1 IV. CALCULATIONS TO CHECK EXISTING CONSTRUCTION Structural calculations shall include the following: A. Derivation of earthquake demand (seismic design) forces and their distribution to resisting elements and connections. Bf Capacities of existing resisting connections. Include materials testing results. elements and C. Capacity/demand ratios (factors of safety) for existing elements and connections. V. CONCLUSIONS AND RECOMMENDATIONS Describe areas found by analysis to be deficient in their ability to withstand prescribed seismic forces, and their significance regarding potential collapse or partial collapse. Discuss in general terms the alternatives available for mitigation of these inadequacies, and the engineer's recommendations for most suitable solutions, in sufficient detail to permit the building owner to obtain cost estimates for repairs. NOTE: Each engineering report shall bear the signature and professional registration number, including its expiration date, of the responsible civil or structural engineer. Appendix B, Page 2 GILROY TENTATIVE URM LIST As of October 26, 1989 On North Monterey Street: 1. 7320 841-08-004 2. 7353 799-08-040 3. 7357 799-08-038 4. 7380 841-08-006 5. 7383/87 799-08-035 6. 7400 841-06-061 7. 7401 799-07-067 8. 7445/47 799-07-056 9. 7450/52 841-06-010 10. 7451 799-07~055 11. 7453 799-07-054 12. 7454/60 841-06-011 13. 7459/61 799-07-052 14. 7463 799-07-052 15. 7477 799-07-050 16. 7511 799-06-054 17. 7515 799-06-053 18. 7517 799-06-052 19. 7525 799-06-051 20. 7529/31 799-06-050 21. 7539/41 799-06-048 22. 7543/47 799-06-047 23. 7557 799-06-045/46 24. 7561/65 799-06-044 25. 7562 841-05-060 26. 7568 841-05-061 27. 7573 799-06-043 28. 7574 841-05-064 29. 3579 799-06-042 30. 7598 841-05-065 31. 7680/B 841-04-018 32 . 7760 841-04-0t9 33. 7888 841-02-009 Banning Upholstery (Milias, R) Vacant (former bar?) (Garcia, Felix) Porcella'.s Music Store (Porcella) Pitzer Automotive (Kishimura*) Augie's Restaurant/Bar (Falk) Old City Hall Restaurant (City) Hall's Western Wear (Hall*) Gilroy Antiques (Garcia, Jesus*) Hair Etc./Downtown Barber (Villa- franca, FY) Nimble Thimble (Gaeta) Zapateria 6 Hermanos (Topland) Boot & Shoe Repair/Cielito Lindo Restaurant (A & W Properties, R, FV) South County Housing/Rainbow Stained Glass (Brown, FV) Kirby's Vaccuum Center (Brownfield*, R, FV) USA Beauty Supply (Ginelli*, R) Monterey Street Antiques (Rizzuto*) California Music Video (Milias, R) Rendi's Boutique (Nicholson) Mr. Art's Shoes (Lang, R, FV) Leedo Gallery (Pratt, FY) Baskets D'Royale/Bruhn Clothiers (Gilroy Improvement Co.*) Western Auto (Ashford*, R) Vacant (former Classique Fashions) (Trinchero*, Buchanan*, R, FY) Bachelors Club/Gilroy Appliance Center (Byers*, FV) Fords Department Store (Ford) Offices (Buena Vista et. al.) (Hagins) Esmeralda's Jewelers (Ferrarini, R) Crumbles Restaurant (Fo~d) Beverly Fabrics (Weaver, R) Rede's Flowers (Machine Shop behind) (Hagins) Gilroy Lock 'n Safe/Kelley's Auto Supply (Sou~h County Alternatives) Monterey Square (Manzo*, R) Antique Mall (Kowk) Elsewhere: 34. 7526/30 Gourmet Alley 799-06-0~.9 35. 55 W. 5th St. 799-06-057 36. 64 W. 5th St. 799-07-044 37. 195 5th St. 799-06-031 38. 60 W. 6th St. 799-08-059 39. 7491 Railroad Ave./ 88 Martin 841-06-00i Lords & Ladys Nail Salon/ Williams Kenpo Karate (Gi!roy improvement Co.) Vacant (Station 55) (Anslinger~) Medical Office (Perry, R, FV) G~roy Museum (City) Diamond Signs (Diamond, R) Storage (Sachara, K) Need to Add: 40. Chen's ResSauran% 41. Vacant (formerly Bakery) *indicates owner or rep at~ended !st public meesing. R = Sent back response form FY = Field visited w/ owner or red New Gl!roy I, SUSANNE E. STEINMETZ, City Clerk of the City of Gilroy, do hereby certify that the attached Ordinance No. 89-20 is an original ordinance, duly adopted by the Council of the City of Gilroy at a regular meeting of said Council held on the 4th day of December , 19 89 , at which meeting a quorum was present. IN WITNESS WHEREOF, I have hereunto set my hand and affixed the Official Seal of the City of Gilroy this 5th day of December 19 89. (Seal)